Waveline EZ Portable Patient Monitor with Touch-Screen

https://www.duraprohealth.com/web/image/product.template/195583/image_1920?unique=bf274c2

3,298.00 3298.0 USD 3,298.00

3,298.00

Not Available For Sale

Please call us for Availability

    This combination does not exist.

    Product Information:

    Product images shown are for illustration purposes only and may not be an exact representation of the product. If you have questions regarding product images click here. The shipping cost provided is an estimate. Actual shipping and handling costs may vary based on the destination, logistics, supply chain challenges, and other shipment requirements. The actual shipping cost will be added to the final invoice.

    ECG, Respiration, SpO2, Noninvasive BP and Temperature. Available with EtCO2 and printer.

    Featuring cutting-edge innovations and impeccable craftsmanship, the DRE Waveline EZ patient monitor is the perfect choice for health care professionals who demand precision, performance and affordability. It features an intuitive touchscreen that helps you quickly and accurately evaluate patient conditions, resulting in better patient care. Utilize the Waveline EZ to monitor ECG, respiration, SpO2, NIBP and temperature; it's also available with EtCO2 monitoring and a printer.

    Features:

    • Weighs only 6 lbs. One of the most mobile multi parameter monitors on the market.
    • Touch-screen provides immediate operation
    • 8 inch high resolution color display
    • Simultaneous multi-lead ECG monitoring
    • Advanced ST and arrhythmia detection
    • Graphical and tabular trending
    • Displays five waveforms
    • Battery backup
    • Audible and visual alarms
    • Quick BP readings recall
    • New - Bigger time stamp in upper right corner
    • New - Standby button
    • New - Revised SpO2 pitch tone is still audible when SpO2 rate decreases
    • New - Volume and Sounds are adjustable and now can be turned off completely
    • New - Option to print Numerical Data Only
    • New - Color of the waveforms can be changed

    Capnography is outpacing Pulse Oximetry as the new standard of care in outpatient surgery procedures. Click to see the dramatic difference between CO2 and SPO2.

    Specifications:

    Physical Dimensions Height: ~8-1/5 inches
    Width: 9 inches
    Length: 4-7/10 inches
    Safety Approval & Quality System Designed to meet IEC60601-1-1988, EN60601-1-1, EN60601-2
    Class II Equipment, double insulated
    Type BF applied parts
    ISO9001 & EN46001 Certified
    Power Requirements Power Supply AC 90-264V/47-63Hz
    Input Power ‰¤55VA
    Fuses Two fuse sockets in the rear panel indicated by "FUSE", OI 5X20, 2A/250V
    Battery 12V/4.0AH sealed lead-acid
    Charge time ‰¥4 hours
    Operating time ‰¥2 hours (full recharge)
    Battery Charging Method Automatic
    Charging after monitor is connected to AC power supply (with charge protection function)
    Discharge Protection When powered by battery, the monitor will be automatically turned off when battery power is almost used up
    ECG Input - (Optional) 5-lead ECG cable and standard AAMI line for connection
    Patient Safety Standard IEC60601-1-1988
    CMRR ‰¥60dB (Common Mode Rejection Ratio)
    Heart Rate Range 20 ~ 254bpm ± 1bpm
    Heart Rate Averaging 8 second average
    ST Segment Range -0.8 ~ + 0.8mV
    Interface AAMI 6-pin
    Lead Selection I, II, III (3 lead mode)
    I, II, III, aVR, aVL, aVF, V (5 lead mode) (ST and Arrhythmia analysis)
    Lead Fault Alarm Audible, Visual Input 5-lead ECG patient cable
    QRS Indicator Audible and Visual Alert
    Waveform Storage 6 minutes
    Sweep Speed 12.5/25/50 mm/sec
    Gain Selection 4mV, 2mV, 1mV, 0.5mV, 0.25mV,Auto
    Trends 2 hours -> 4 hours -> 8 hours -> 24 hours -> 48 hours
    Patient Isolation Breakdown voltage 4000VAC 50Hz 60 seconds Leakage current <10μA
    Frequency width Monitoring mode 0.5 ~ 40Hz (+0.4dB,-3.0dB) Surgery mode 0.5 ~ 20Hz (+0.4dB, -3.0dB) not calibration significant
    Patient Drive Current <10μA
    Enclosure Leakage Current <0.1mA
    Maximum T Wave Rejection Capability 1.2mV
    Heart Rate Alarm Response Time < 7 seconds
    Aspect Ratio 0.24 ~ 0.6 sec/mV
    Alarm Frequency Low alarm: 2-2.4kHz High alarm: 3-3.4kHz
    Defibrillator Protected & ESIS Protected Tested with 5kV
    Recovery Time Following Defibrillation <5 seconds
    Respiration Measurement Method Thoracic Impedance
    Respiration Rate Range 0 ~ 100±1rpm
    Accuracy ±2 rpm
    Pulse Oximetry (SpO2) SpO2 Range 0-100% Adult/Pediatric/Neonate
    SpO2 Averaging 8 second average
    SpO2 Accuracy ±2% (70 ~ 100%), ±3% (40 ~ 70%)
    Pulse Rate Range 30 ~ 250bpm
    Pulse Rate Averaging 8 beat average
    Pulse Rate Accuracy ±1% @ 30 ~ 100bpm
    Sensor Types Finger, Universal "Y", wrap probes
    Pulse Rate Display Digital
    Non-Invasive Blood Pressure (NIBP) Method Automatic oscillometric
    Parameters Systolic, diastolic, mean arterial pressure, pulse
    Scale mmHg or kPa
    Operating Modes Manual, Automatic, Continuous
    Repeat Cycles 1 ~ 10, 15, 30, 60, 90, 120 minutes
    Determination Systolic, Adult/pediatric 40 ~ 250mmHg (5.3 ~ 33.3kPa) Systolic, Neonate 20 ~ 160mmHg (2.7 ~ 21.3kPa) Diastolic, Adult/pediatric 10 ~ 180mmHg (1.3 ~ 24.0kPa) Diastolic, Neonate 10 ~ 140mmHg (1.3 ~ 18.7kPa)
    Cuff Pressure Range Adult/pediatric 0 ~ 300mmHg (0 ~ 40.0kPa) Neonate 0 ~ 140mmHg (0 ~ 18.7kPa)
    Initial Cuff Inflation Adult/pediatric 170±10mmHg (22.7±1.3kPa) Neonate 100±10mmHg (16.0±1.3kPa)
    Deflation Pressure 30mmHg(4.0kPa) higher than the last systolic pressure
    Cuff Inflation Rate No greater than 50mmHg/sec
    Measurement Time Typical 25 seconds, Maximum 40 seconds, Typical Stat 20 seconds
    Pressure Display Accuracy ±3mmHg
    BP Pulse Rate Accuracy ±2% @ 40 ~240bpm
    Cuff Neonate, infant, pediatric, standard adult
    Temperature (Dual Channel) Range 0 ~ 50°C
    Probe YSI ® 400 Skin surface or rectal /esophageal
    Scale Celsius
    Accuracy ±0.1°C
    Resolution 0.1°C
    CO2 Type Side stream, mom-dispersive IR
    CO2 Range 0-99mmHg
    Scale mmHg/kPa
    Accuracy ± 2mmHg (0-40mmHg) ± 5mmHg (41-76mmHg) ±10mmHg (77-99mmHg)
    Calibration Automatic
    Respiration Range 0-150rpm, ± 2rpm
    TFT Color Display Size 8 inches Matrix 640 (H) × 480 (V) pixels
    Recorder (Optional) Type Built-in 2-channel thermal array recorder
    Print mode Text or waveform
    Waveforms Real time or alarm-triggered
    Resolution 400dpi vertical, 800dpi horizontal
    Annotations Time, date, vital sign readings