User-friendly touch-screen patient monitor measures ECG, SpO2, NIBP, heart rate, temperature and respiration. Offers optional dual IBP, and EtCo2.
The fully-functional Waveline Touch features a 12.1" color TFT display with a touch-screen interface. It features multi-lead ECG monitoring, ST segment monitoring and 72 hours trend data analysis.
Features:
- New - Optional Plug-In Anesthesia Gas Module expands measurement capabilities €” Anesthesia Gas Module
- New - Bigger time stamp in upper right corner
- New - Standby button
- New - Revised SpO2 pitch tone is still audible when SpO2 rate decreases
- New - Volume and Sounds are adjustable and now can be turned off completely
- New - Option to print Numerical Data Only
- New - Color of the waveforms can be changed
- EtCO2 Option allows compliance with ASA
- Available with optional dual invasive blood pressures, EtCO2, a battery and a built-in recorder.
- 12.1" color TFT display with a touch-screen interface
- Multi-lead ECG monitoring
- Built-in battery (optional)
- NIBP list display
- OxyCRG dynamic view display
- Built-in thermal recorder
- Networkable with a central monitoring system via a wireless or wired network
- S-T Segment and 72 hours trend data analysis
- Compact design convenient for mobile monitoring
- Drug dose calculations
- Multi-lingual settings
Specifications:
Physical Weight & Dimensions |
Weight: 5kg Height: ~11 inches |
Length: ~6-1/5 inches Width: ~12 3/5 inches |
Application | Neonatal, pediatric and adult patients | |
Operation Environment |
Power Source - External AC power or internal battery AC Power - 100-240VAC, 50/60Hz, <150VA |
Battery - Rechargeable Lead-Acid; Operating time under the normal condition (1 hour); Operating time after the first alarm of low battery (10 min.) |
Temperature |
Working - 5°-40° C Storage - -20°-65° C |
|
Performance Specifications |
Display - 12.1" color TFT, Touch Screen Resolution - 800 × 600 pixels Trace - 4, 6 or 8 waveforms ECG (I, II, III, aVR, aVL, aVF, V1-V6), PLETH, RESP, IBPx2, ETCO2 Indicator - Alarm indicator; Power indicator QRS beep and alarm sound |
Trend Time - 72 hours Recorder - Built-in, thermal array, 2 channels Record - Width 48mm Recorder - Paper 50mm Record - Speed 25mm/s, 50mm/s |
ECG |
Input - 3-lead ECG cable and standard AAMI line for connection Input - (Optional) 5-lead ECG cable and standard AAMI line for connection Lead Choice - I, II, III, aVR, aVF, aVL, V Gain Choice - x0.5, x1.0, x2.0 Frequency Characteristic - 0.05-40 Hz ECG Waveforms - 7 channels |
Penetration Voltage - 4000VAC 50/60Hz Sweep Speed - 12.5, 25 and 50 mm/s HR Display Range - 30-300bpm Accuracy - ±1% or ±1bpm, whichever is greater Alarm Limit Range Setting - Upper limit 80-400bpm; Lower limit 20-150bpm |
RESP |
Measure Method - RA-LL impedance Range - 0-120 rpm Accuracy - + 3 rpm |
Alarm Upper-lower Limit Setting - Upper limit 6-120 rpm, Lower limit 3-120 rpm Sweep Speed - 12.5 and 25 mm/s |
NIBP (Suntech) |
Measuring Technology - Automatic oscillating measurement Cuff Inflating - <30s-0-300 mmHg, standard adult cuff Measuring Period - AVE<40s Mode - Manual, Auto, STAT Measuring Interval in AUTO Mode - 2 min-4 hrs Pulse Rate Range - 30-250 (bpm) |
Measuring Range - Adult/Pediatric Mode, SYS 40-250 (mmHg), DIA 15-200 (mmHg); Neonatal Mode, SYS 40-135 (mmHg), DIA 15-100 (mmHg) Resolution - 1mmHg Accuracy - Pressure, Maximum Mean error ±5mmHg, Max. Standard deviation 8mmHg Overpressure Protection - Adult Mode 280(mmHg), Neonatal Mode 150 (mmHg) Alarm Limit Setting - SYS 50-240 mmHg, DIA 15-180 mmHg |
TEMP |
Range - 25°-50° C Accuracy - + 0.2 °C 25.0°-34.9° C; + 0.1° C 35.0°-39.9° C; + 0.2° C 40.0°-44.9° C; 0.3° C 45.0°-50.0° C Display Resolution - 0.1° C |
Alarm Upper-lower Limit Setting - Upper limit 0-50° C, Lower limit 0-50° C Channel - 2 channels Alarm Limit Setting - 10-50° C |
SPO2 |
ASpO2 Anti-motion SpO2 SpO2% Range 0-100% SpO2 Accuracy + 2% 70-100%, nonmotion; + 3% 70-100%, motion Pulse Rate Range 30-250 bpm Pulse Rate Accuracy ±2 bpm (non-motion); ±3 bpm (motion) |
Alarm Upper-lower Limit Setting: Upper limit 70-100%, Lower limit 70-100% SpO2 Probe - Red Light LED Wavelength 660nm±5nm, Infrared Light LED Wavelength - 940nm±10nm |
IBP (Option) |
Measurement Range - -10-300mmHg Channel - 2 channels Pressure Transducer Sensitivity, 5μV/V/mmHg Impedance Range - 300-3000Ω |
Transducer Sites - ART, PA, CVP, RAP, LAP, ICP Resolution - 1mmHg Accuracy - ±1mmHg or ±2%, whichever is greater Alarm range - -10-300mmHg |
EtCO2 (Option) |
EtCO2 Option allows compliance with ASA Standards for Basic Anesthetic Monitoring (Effective July 1, 2011) Mode of Sampling - Sidestream Principle of Operation -Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts CO2 Measurement Range - 0 to 150 mmHg (0 to 19.7%, 0 to 20 kPa) CO2 Calculation Method - BTPS (Body Temperature Pressure Saturated) CO2 Resolution - 0.1mmHg(0-69mmHg); 0.25mmHg(70-150mmHg) |
CO2 Accuracy - 0-40 mmHg ± 2 mmHg; 41-70 mmHg ± 5% of reading; 71-100 mmHg ± 8% of reading; 101-150 mmHg ± 10% of reading; Above 80 breath per minute ± 12% of reading Sampling Rate - 100Hz Respiration Rate - 2-150 bpm Respiration Rate Accuracy - ±1 breath Response Time - <3 seconds - includes transport time and rise time Inspired CO2 Measurement Range - 3-50 mmHg |
Waveline Touch Patient Monitor with Touch-Screen
- Products Model: DRE Waveline Touch
- Manufacturer: Avante Health Solutions
- Condition: New
- Warranty: Call for Details
Share this Product