Avante DRE Echo CO2 Monitor
Product Information:
- Products Model: 60129CRS
- Product Brand: Avante Health Solutions
- Condition: New
- Warranty: Satisfaction Guaranteed
Product images shown are for illustration purposes only and may not be an exact representation of the product. If you have questions regarding product images click here. The shipping cost provided is an estimate. Actual shipping and handling costs may vary based on the destination, logistics, supply chain challenges, and other shipment requirements. The actual shipping cost will be added to the final invoice.
Ultra-lightweight and portable with a 10 hr battery.
Pre-op/post-op vital signs monitor
The accurate, cost-effective DRE Echo vital signs monitor is available in configurations with your choice of SpO2, NIBP and Temperature. The portable monitor has multi-parameter functionality suited for out-patient care and doctor's offices.
FEATURES
Covidien Quick Temp Technology
5.7 inch high resolution display for easy reading
Flexible configurations
Built-in rechargeable Lithium-ion battery for 10 hours of continuous working
Optional thermometer for obtaining temperature in approximately 15 seconds
Real-time parameters measurement display with trend table for easy reviewing
Bi-directional communications with central station by wired or wireless network
Nellcor OximaxTM
Suitable for adult, pediatric and neonatal patient
PR measurement (from SpO2/ NIBP)
Optional recorder
SPECIFICATIONS
General
- Size: 200.8mm (L) × 241mm (H) × 189 mm (D)
- Weight: 3 kg
- Display: 5.7 inches,LCD
- Color TFT resolution: 640X480
- Power Supply: 100-240 VAC, 50/60HZ
- Pmax=70VA FUSE T 1.6AL
- Battery Type: Lithium-ion
- Voltage: 14.8 V DC Capacitance: 4,400 mAh
- Working period: Color TFT 480min
- Rechargeable period: < 360min
- Recorder: (Optional)
- Record Width: 48 mm
NIBP
- Method: Oscillometric
- Mode: Manual, Auto, Continuous
- Measuring Interval in AUTO Mode: 1/2/3/4/5/10/15/30/60/90/120/240/480 Min
- Continuous: 5min, interval is 5s
- Measuring Type: Systolic Pressure, Diastolic Pressure, Mean Pressure, Measuring Range
- Adult Mode:
- SYS: 40~270mmHg
- DIA: 10~215mmHg
- MAP: 20~235mmHg
- Pediatric Mode:
- SYS: 40~200mmHg
- DIA: 10~150mmHg
- MAP: 20~165mmHg
- Neonatal Mode:
- SYS: 40~135mmHg
- DIA: 10~100mmHg
- MAP: 20~110mmHg
- Cuff Pressure measuring Range: 0~290mmHg
- Pressure Resolution: 1mmHg
- Maximun mean error: 5mmHg
- Maximum Standard deviation: 8mmHg
- Entire Measuring Period 30~45s typical (depend on HR/motion disturbance)
- Dual Overpressure protection:
- Adult: 297 3mmHg
- Pediatric: 240 3mmHg
- Neonatal: 145 3mmHg
- PR:
- Measuring Range: 40~240bpm
- Resolution: 1bpm
- Accuracy: 3bpm or 3% of the maximum
- IEC 60601-2-30
SpO2
- Resolution: 1 %
- Accuracy
- Adult (including Pediatric):
- 2% 70%~100% SpO2
- Undefined 0~70% SpO2
- Neonate:
- 3% 70%~100% SpO2
- Undefined 0~70% SpO2
- Measuring Range: 0 ~ 100 %
- Alarm Range: 0 ~ 100 %
- Pulse Rate:
- Measuring and Alarm Range: 30 ~ 300bpm
- Resolution: 1bpm
- Accuracy: 3bpm
- Data update period: 2s
- ISO 9919